CVI
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text (PDF)
Right arrow Other Versions of this Article:
CVI.00171-07v1
14/7/929    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Girmenia, C.
Right arrow Articles by Martino, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Girmenia, C.
Right arrow Articles by Martino, P.

 Previous Article

Clinical and Vaccine Immunology, July 2007, p. 929, Vol. 14, No. 7
1071-412X/07/$08.00+0     doi:10.1128/CVI.00171-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.

LETTER TO THE EDITOR

Contamination by Cardboard Particles as a Cause of False-Positive Results for Aspergillus Galactomannan Enzyme Immunoassays{triangledown}


    LETTER
 Top
 LETTER
 REFERENCES
 
Galactomannan (GM) detection by the Platelia Aspergillus enzyme immunoassay is widely used for diagnosing invasive aspergillosis. A major problem with the detection of circulating GM is the occurrence of false-positive results due to the cross-reactivity of the test with antigens other than Aspergillus GM. In the clinical setting, cross-reactivity with antibiotics, in particular piperacillin-tazobactam, and other opportunistic fungi represent the two major causes of false-positive results (3, 5). Gastrointestinal translocation of GM from food is also a presumed cause of false positivity for antigenemia (5). Recently, solutions containing gluconate, which is usually produced by fermentation of glucose in mold cultures, have been shown to be another cause of false-positive GM assay reactivity (4, 6).

At our institution, GM assay is routinely used in the diagnosis of invasive aspergillosis in patients with hematologic malignancies. In March 2007, in two consecutive experiments, all serum samples (32 samples total) showed very high indexes of reactivity (indexes of >4) with normal reactivity to negative, positive, and standard serum controls provided by the manufacturer. Considering that most of these results were not consistent with the clinical findings for the patients and that the patients had no specific clinical characteristic in common (they were adult and pediatric inpatients and outpatients with various underlying diseases and conditions), we hypothesized that Platelia Aspergillus positivity may have been due to a cross-reaction related to an abnormal laboratory procedure. Initially, no particular handling practice during assay performance potentially leading to the contamination of samples was identified. Finally, we found out that while the tubes (1.5-ml Eppendorf microcentrifuge tubes) we use for serum sample storage in our laboratory are usually taken from a plastic box, in the two above-described experiments the laboratory technician erroneously used the same type of tubes but took them from a cardboard box (the control samples had previously been stored in tubes from the plastic box). The tubes, not plugged as provided by the manufacturer, had been placed in the cardboard box and the box in a laboratory cupboard several months before, and some cardboard particles were visible. We performed the GM assay with sterile distilled water using tubes taken from the cardboard box and with cardboard homogenate, and all gave high indexes of reactivity. Multiple cultures of tubes and cardboard were negative for fungi.

Polysaccharides containing mannopyrosyl residues, such as mannans, glucomannans, and GMs, are commonly found as plant cell wall components (1). Considering that paper and paper products are made from plants, it seems reasonable to hypothesize that cardboard particles contain GM antigen cross-reacting with the Platelia Aspergillus assay. Similar cross-reaction was also reported for cotton swabs (2). Therefore, we think that the false-positive GM results we observed in the above-described experiments were related to the prior contamination of the tubes by cardboard particles before their use for serum sample storage. Although enzyme immunoassay procedures usually do not require particular sterility precautions, considering that GMs are polysaccharides widely distributed in the environment, improper laboratory practices possibly allowing contamination and false-positive results should be known and carefully avoided.


    FOOTNOTES
 
{triangledown} Published ahead of print on 9 May 2007. Back


    REFERENCES
 Top
 LETTER
 REFERENCES
 

  1. Bacic, A., P. J. Harris, and B. A. Stone. 1988. Structure and function of plant cell walls, p. 297-371. In J. Preiss (ed.), The biochemistry of plants—a comprehensive treatise, vol. 14. Carbohydrates. Academic Press, New York, NY.
  2. Dalle, F., J. Lopez, J. D. Caillot, D. B. Cuisenier, L. A. Ecarnot, L. Dumont, and A. Bonnin. 2002. False positive results caused by cotton swabs in commercial Aspergillus antigen latex agglutination test. Eur. J. Clin. Microbiol. Infect. Dis. 21:130-132.[CrossRef][Medline]
  3. Giacchino, M., N. Chiapello, S. Bezzio, F. Fagioli, P. Saracco, A. Alfarano, V. Martini, G. Cimino, P. Martino, and C. Girmenia. 2006. Aspergillus galactomannan enzyme-linked immunosorbent assay cross-reactivity caused by invasive Geotrichum capitatum. J. Clin. Microbiol. 44:3432-3434.[Abstract/Free Full Text]
  4. Hage, C. A., J. M. Reynolds, M. Durkin, L. J. Wheat, and K. S. Knox. 2007. Plasmalyte as a cause of false-positive results for Aspergillus galactomannan in bronchoalveolar lavage fluid. J. Clin. Microbiol. 45:676-677.[Free Full Text]
  5. Mennink-Kersten, M. A., J. P. Donnelly, and P. E. Verweij. 2004. Detection of circulating galactomannan for the diagnosis and management of invasive aspergillosis. Lancet Infect. Dis. 4:349-357.[CrossRef][Medline]
  6. Surmont, I., and W. Stockman. 2007. Gluconate-containing intravenous solutions: another cause of false-positive galactomannan assay reactivity. J. Clin. Microbiol. 45:1373.[Free Full Text]
Corrado Girmenia*
Daniele Ballarò
Pietro Martino

Dipartimento di Biotecnologie Cellulari ed. Ematologia
University "La Sapienza" of Rome
Via Benevento 6
00161 Rome, Italy

* Phone: 39-06-857951, Fax: 39-06-44241984, E-mail: girmenia{at}bce.uniroma1.it


Clinical and Vaccine Immunology, July 2007, p. 929, Vol. 14, No. 7
1071-412X/07/$08.00+0     doi:10.1128/CVI.00171-07
Copyright © 2007, American Society for Microbiology. All Rights Reserved.





This Article
Right arrow Full Text (PDF)
Right arrow Other Versions of this Article:
CVI.00171-07v1
14/7/929    most recent
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Girmenia, C.
Right arrow Articles by Martino, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Girmenia, C.
Right arrow Articles by Martino, P.


Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev. Infect. Immun.
J. Clin. Microbiol. J. Virol. ALL ASM JOURNALS