Dörthe Externest,
M. Alexander Schmidt, and Andreas Frey*
Institut für Infektiologie, Zentrum für Molekularbiologie der Entzündung, Westfälische Wilhelms-Universität, D-48149 Münster, Germany
Received 4 March 2003/ Returned for modification 30 April 2003/ Accepted 9 June 2003
| ABSTRACT |
|---|
|
|
|---|
1 mg of antigen per g of body weight), when transudation rates of up to 31% could be measured in filter wick-collected samples from individual animals. Luminal IgG was plasma transudate and/or bile borne and appeared to be reabsorbed at the mucosa to some extent. | INTRODUCTION |
|---|
|
|
|---|
| MATERIALS AND METHODS |
|---|
|
|
|---|
Determination of transudation marker and immunoglobulin concentrations. Murine serum albumin (MSA) was chosen as the transudation marker and was assayed by capture enzyme-linked immunosorbent assay. Each well of high-binding enzyme immunoassay plates (Corning Costar, Bodenheim, Germany) were coated with 75 µl of 40 ng of goat anti-mouse albumin (Bethyl, Montgomery, Tenn.) per ml in 10 mM sodium phosphate (pH 7.0)-10 mM NaCl overnight at 4°C, washed three times with Dulbecco's phosphate-buffered saline (D-PBS) containing 0.05% (vol/vol) Tween 20, and blocked with D-PBS containing 5% (wt/vol) nonfat dry milk (PBS-Blotto) for 5 h at room temperature. After four washes, 75 µl of serially diluted samples and immunoglobulin-free MSA standard (ICN, Eschwege, Germany) in PBS-Blotto were applied to each well and the plates were incubated overnight at 4°C. After another four washes, 75 µl of horseradish peroxidase-labeled goat anti-mouse albumin (Bethyl) diluted 1:1,000 in PBS-Blotto was applied to each well, the plates were incubated for 90 min at room temperature and again washed six times, and the color was developed by using a highly sensitive tetramethylbenzidine substrate reagent (3).
Quantitation of total and specific immunoglobulins was carried out as described previously (2). Antibody cross-reactivities were determined under conditions analogous to those of the quantitation of total immunoglobulins as the ratios of the detection limits for the potentially cross-reacting analyte to those for the original target analyte.
Total MSA and immunoglobulin concentrations were determined on the basis of four-parameter curve fit approximations of standard titration curves by using the readouts for the unknown samples at the steepest slopes of their titration curves (SOFTmax Pro, version 1.0; Molecular Devices, Sunnyvale, Calif.). Specific antibody responses were expressed as endpoint titers, being the reciprocal for the highest dilution that gave a reading above the cutoff, with the cutoff being the upper limit of a 99.5% confidence interval above the mean control level (4).
For determination of the relative amount of serum antibody transudate in a mucosal sample, unhindered plasma flow was assumed for the site of leakage (i.e., leakage of immunoglobulin analyte and serum marker transudate equally well). With this, the ratio of the concentration of transudating immunoglobulin analyte to the concentration of the transudating marker is identical for the serum and the mucosal sample, as expressed by equation 1:
![]() | (1) |
![]() | (2) |
![]() | (3) |
![]() | (4) |
In this equation, all variables except the relative amount of marker in the mucosal sample are experimentally accessible, but the relative amount of marker in the mucosal sample can safely be set to 100% in the case of MSA since serum albumin is neither produced nor actively transported by the mucosal epithelium.
On the basis of equation 4, mucosal immunoglobulins that are entirely plasma derived must display transudation rates close to 100%, whereas active translocation results in rates below this level and active absorption results in rates above this level.
Data analysis. Statistical analyses were carried out with the Statview program (version 4.5; Abacus Concepts, Berkeley, Calif.). Between-group comparisons were performed by one-way analysis of variance (one-way ANOVA) with Fisher's protected least significant difference test. Paired t tests were used for paired samples. The results of the statistical analyses were considered significant only if P was <0.05.
| RESULTS AND DISCUSSION |
|---|
|
|
|---|
Total transudation marker and immunoglobulin contents in sampled specimens.
For the MSA contents of the specimens sampled by invasive means, i.e., serum, intestinal lavage fluid, and filter wick-collected samples, no persistent statistically significant differences between the different immunization groups were observed (one-way ANOVA, P
0.056), which indicates that all groups were comparable with respect to their serum marker concentration and were treated alike during sample collection. The total MSA and immunoglobulin concentrations of all samples along with the relative amounts of serum IgA and IgG in mucosal samples are given in Table 1.
|
0.096 and P = 0.44, respectively). Averaged over all groups and both collection sites, plasma leakage accounted for 1.75% ± 0.14% (mean ± SEM; n = 47) of filter wick-extracted IgA. Compared to that value, the relative amounts of transudated IgA in feces and intestinal lavage fluid were significantly lower (one-way ANOVA, P
0.005) and not significantly different from each other, neither when the amounts for individual immunization groups nor when the averages over all groups were compared (one-way ANOVA, P
0.26 and P = 0.58, respectively). Since the transudate content of feces reflects the naturally occurring baseline level of plasma leakage, the filter wick absorption procedure clearly generates artifactually higher IgA measurements for mucosal secretions. The reason for this may be attributed either to physical damage of the epithelium caused by application of the filter wicks or to capillary suction of the filter fabric. In light of this observation, it is important to elucidate the conditions under which artifactual serum IgA leakage caused by filter wicks is tolerable or not. As the filter wick absorption procedure is predominantly used to analyze antibody immune responses after mucosal infection or immunization, we also determined the transudation rates of specific serum IgA after experimental mucosal immunization (Table 2). Again, serum IgA transudation was highest in filter wick-collected samples, but in contrast to total IgA, transudation of specific IgA turned out to be antigen dose dependent.
|
2 mg of ovalbumin (i.e., for the groups receiving 0.2 and 2 mg combined), the amount of specific serum IgA in filter wick-collected samples did not differ significantly from that in feces or intestinal lavage fluid, no matter whether filter wick-collected samples from the proximal and the distal small intestine were analyzed separately or the average for both sites was used for comparison (one-way ANOVA, P
0.071). The contributions of serum IgA to the mucosal secretion titers for these antigen doses were 0.23% ± 0.08% (mean ± SEM; n = 12) in feces, 0.33% ± 0.19% (mean ± SEM; n = 12) in small intestinal lavage fluid, and 0.70% ± 0.15% (mean ± SEM for both sampling sites; n = 24) in filter wick-collected samples, with the highest rate in an individual animal being 3.5%.
However, when 20 mg of antigen, which corresponds to 1.25 mg of antigen per g of body weight of the mice at the day of priming (body weight, 16.02 ± 0.60 g [mean ± SEM; n = 6]), was used, a dramatic increase in the relative amount of specific serum IgA in filter wick-collected samples was observed. It reached up to 31% in individual animals and was significantly different from those in feces and intestinal lavage fluid (one-way ANOVA, P
0.007).
We attribute this to the high specific serum IgA titers generated by such an antigen dose and conclude that the filter wick absorption procedure is prone to erroneous results when high serum IgA titers and/or low secretory IgA titers are expected. J-chain-knockout (7, 11) or polymeric immunoglobulin receptor-knockout (8) mice, which are presumed to be deficient in secretory IgA production but which show up to 35-fold higher total serum IgA titers, are a prototype example for this constraint. For these animals, plasma-derived monomeric IgA should give rise to amounts of IgA in filter wick-collected samples nearly similar to those in wild-type animals. In view of this, it seems questionable whether alternative transport mechanisms are responsible for the high levels of monomeric IgA in filter wick-collected specimens from jch-/- mice, as proposed by Hendrickson et al. (7).
For applications other than that, however, the filter wick absorption procedure appears to be well suited for determination of the secretory IgA status at mucosal surfaces. Even for extreme hyperimmunizations, like those achieved with the 20-mg dose (which, in case of human applications, would translate into the enormous dose of about 15 g of antigen for a 2-year-old toddler on the basis of body weight), almost 90% of the specific IgA in a filter wick-collected sample is still locally produced; and it seems unlikely that an average deviation of 0.7% for moderate antigen doses would affect titer readouts for serially diluted samples to a significant extent. In support of this assumption, we observed that correlations between specific antibody titers in serum and filter wick-collected intestinal secretions vanish with increasing antigen doses (2). If the contribution of plasma transudate-derived IgA to the readouts for filter wick-collected samples had been of significance, these correlations should have increased along with the antigen dose instead of going down.
Thus, in wild-type mice more than 98% of total and specific mucosal IgA antibodies which have been sampled by either procedure are true secretory IgA antibodies; i.e., the IgA is dimeric or polymeric and carries the secretory component. This is in good agreement with data obtained by use of yet another sampling procedure, the so-called perfusion extraction method, by which serum IgA transudation rates of 1.5% have been measured for the murine small intestine (9). The transudation rates obtained for mice by either sampling technique also correspond well to those in the human small intestine, in which 98% of luminal IgA was found to be of the secretory type (10).
On the basis of our data, however, it is difficult to assess where the secretory IgA antibodies are in fact transported. In addition to the intestinal epithelium, the hepatobiliary system constitutes another translocation site for those immunoglobulins. Even filter wick-collected specimens may contain bile-derived secretory IgA that diffused from the lumen of the gut toward the epithelial layer. This concern is of particular relevance in the murine system, since rodents were shown to have a considerably higher biliary secretory IgA transport rate than humans (1).
Transudation of serum IgG into feces, intestinal lavage fluid, and filter wick-collected samples. Since IgG is believed to be not actively transported across the intestinal epithelium in adult rodents, we expected transudation rates of about 100% for this immunoglobulin and the ratio of the MSA concentration to the total IgG concentration to be identical to that for serum in all mucosal sample types. This, however, was not the case.
When the data for all groups were combined, the MSA concentration to total IgG concentration ratios were significantly lower for feces and intestinal lavage fluid (two-tailed, paired t test, P = 0.044 and P < 0.0001, respectively) and significantly higher for filter wick-collected samples than for serum (two-tailed, paired t test, P
0.015). Ratios were also significantly lower for gut lavage fluid than for feces (two-tailed, paired t test, P = 0.005) but not different between filter wick-collected specimens from the two sites (two-tailed, paired t test, P = 0.43). When the data were analyzed by group, the same tendency was observed, but there were fewer significant differences.
According to these data, the amount of IgG collected from small intestinal surfaces with filter wicks was less than the amount expected from the MSA contents of these samples, resulting in IgG transudation rates above 100% (Table 1). IgG must therefore be either actively reabsorbed at the intestinal epithelium or more rapidly degraded than MSA. Which of these possibilities finally holds true cannot be assessed on the basis of the present data. However, our measurements clearly indicate that IgG is not actively transported across the small intestinal epithelium into the lumen of the gut. This is not in conflict with the observation that about 60% of the IgG in intestinal lavage fluid is locally produced, since luminal IgG can be bile derived in mice (1). While en route to the large intestine, part of this bile-derived IgG may again either be broken down more rapidly than MSA or be reabsorbed, which would explain the nominally higher transudation rate which we observed for feces.
Conclusions.
Taken together, we showed that the three samples commonly used for detection of intestinal IgA, i.e., fecal samples, intestinal lavage fluid specimens, and filter wick-collected specimens, are equally reliable for wild-type mice with respect to artifactually caused plasma leakage. Only in situations in which extremely high serum IgA concentrations are to be expected, like in J-chain- or polymeric immunoglobulin receptor-knockout mice, the filter wick procedure may provide erroneously high readouts due to contaminating serum IgA transudate. In addition to these technical aspects, we showed that in mice
98% of intestinal IgA is of the secretory type, whereas the majority of intestinal IgG appears to be plasma transudate or bile derived.
| ACKNOWLEDGMENTS |
|---|
| FOOTNOTES |
|---|
Present address: Forschungszentrum Borstel, D-23845 Borstel, Germany. ![]()
Present address: Wyeth-Pharma, D-48159 Münster, Germany. ![]()
| REFERENCES |
|---|
|
|
|---|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Antimicrob. Agents Chemother. | Clin. Microbiol. Rev. | Infect. Immun. |
|---|---|---|
| J. Clin. Microbiol. | J. Virol. | ALL ASM JOURNALS |