CVI
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowReprints and Permissions
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gaber, F.
Right arrow Articles by Kapil, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gaber, F.
Right arrow Articles by Kapil, S.

 Previous Article  |  Next Article 

Clinical and Diagnostic Laboratory Immunology, July 1999, p. 542-544, Vol. 6, No. 4
1071-412X/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.

Development of an Antigen Spot Test for Detection of Coronavirus in Bovine Fecal Samples

Fathy Gaber and Sanjay Kapil*

Department of Diagnostic Medicine-Pathobiology, College of Veterinary Medicine, Kansas State University, Manhattan, Kansas 66506

Received 3 March 1999/Returned for modification 21 April 1999/Accepted 26 April 1999

We have developed a rapid and sensitive microimmunodot blot assay, the antigen spot test (AST), for the detection of bovine coronavirus (BCV) antigen from neonatal calf fecal samples. The AST procedure can be completed in 3.5 h, whereas the previously reported immunodot blot assays require 10 to 12 h. Ninety-six samples can be tested per membrane, and 10 membranes (960 samples) may be processed by a single technologist in 1 working day. The effects of detergents, oxidizing chemicals, chaotropic agents, and enzyme substrates in improving the sensitivity and signal-to-noise ratio of the AST were studied. Finally, the sensitivity and specificity of AST for the detection of BCV antigen were compared to those of a sandwich enzyme-linked immunosorbant assay (ELISA) and a hemagglutination assay (HA). Of 347 field samples tested by all three methods, 94.2% were positive by AST, 91.4% were positive by ELISA, and 86.7% were positive by HA. The sensitivity of the AST was determined to be 100% compared to the results of the ELISA reference method. The specificity of the AST was 67%, which reflects a lower limit of detection of 104 viral particles per ml in a 10% fecal suspension.


* Corresponding author. Mailing address: Department of Diagnostic Medicine-Pathobiology, College of Veterinary Medicine, Kansas State University, 1800 Denison Ave., Manhattan, KS 66506. Phone: (785) 532-4457. Fax: (785) 532-4829. E-mail: kapil{at}vet.ksu.edu.


Clinical and Diagnostic Laboratory Immunology, July 1999, p. 542-544, Vol. 6, No. 4
1071-412X/99/$04.00+0
Copyright © 1999, American Society for Microbiology. All rights reserved.






Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev. Infect. Immun.
J. Clin. Microbiol. J. Virol. ALL ASM JOURNALS

Copyright © 1999 by the American Society for Microbiology. All rights reserved.