CVI
Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Copyright Information
Right arrow Books from ASM Press
Right arrow MicrobeWorld
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Anderson, G. P.
Right arrow Articles by Ezzell, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Anderson, G. P.
Right arrow Articles by Ezzell, J.

Clinical and Diagnostic Laboratory Immunology, September 1998, p. 609-612, Vol. 5, No. 5
1071-412X/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.

Quantifying Serum Antiplague Antibody with a Fiber-Optic Biosensor

George P. Anderson,1,* Keeley D. King,2 Lynn K. Cao,2 Meagan Jacoby,1 Frances S. Ligler,1 and John Ezzell3

Center for Bio/Molecular Science and Engineering, Naval Research Laboratory, Washington, D.C.,1 and Geo-Centers Inc., Fort Washington,2 and Applied Research Division, U.S. Army Medical Research Institute of Infectious Disease, Fort Detrick,3 Maryland

Received 29 January 1998/Returned for modification 9 April 1998/Accepted 20 May 1998

The fiber-optic biosensor, originally developed to detect hazardous biological agents such as protein toxins or bacterial cells, has been utilized to quantify the concentration of serum antiplague antibodies. This biosensor has been used to detect and quantify the plague fraction 1 antigen in serum, plasma, and whole-blood samples, but its ability to quantify serum antibodies has not been demonstrated. By using a competitive assay, the concentration of serum antiplague antibodies was ascertained in the range of 2 to 15 µg/ml. By making simple dilutions, concentrations for 11 serum samples whose antiplague antibody concentrations were unknown were determined and were found to be in good agreement with enzyme-linked immunosorbent assay results. The competitive assay method could be used to effectively determine the exposure to plague of animals or humans or could be applied to other diseases, such as hepatitis or AIDS, where the presence of antibodies is used to diagnose infection.


* Corresponding author. Mailing address: Center for Bio/Molecular Science and Engineering, Naval Research Laboratory, Code 6910, Washington, DC 20375-5348. Phone: (202) 404-6033. Fax: (202) 404-8897. E-mail: ganderson{at}cbmse.nrl.navy.mil.


Clinical and Diagnostic Laboratory Immunology, September 1998, p. 609-612, Vol. 5, No. 5
1071-412X/98/$04.00+0
Copyright © 1998, American Society for Microbiology. All rights reserved.






Home Help [Feedback] [For Subscribers] [Archive] [Search] [Contents]
Antimicrob. Agents Chemother. Clin. Microbiol. Rev. Infect. Immun.
J. Clin. Microbiol. J. Virol. ALL ASM JOURNALS

Copyright © 1998 by the American Society for Microbiology. All rights reserved.