Previous Article | Next Article ![]()
Clinical and Vaccine Immunology, May 2009, p. 739-748, Vol. 16, No. 5
1071-412X/09/$08.00+0 doi:10.1128/CVI.00478-08
Copyright © 2009, American Society for Microbiology. All Rights Reserved.

Erica Wagner,1,
Sheri K. Shalkowski,1,
Susan Secore,2
Annaliesa S. Anderson,2,
James Cook,2
Leslie Cope,2
Tessie McNeely,2
Mary Retzlaff,3
Jon Shanter,3
Leonard J. Rubinstein,5
Tina Green,4,
N. Kartsonis,5 and
Mark T. Esser1,
Wayne Clinical Support, Merck Research Laboratories, 466 Devon Park Dr., Wayne, Pennsylvania 19087-8630,1 Vaccine Basic Research, Merck Research Laboratories, West Point, Pennsylvania 19486,2 Bioprocess Research and Development, Merck Research Laboratories, West Point, Pennsylvania 19486,3 Non-Clinical Statistics, Merck Research Laboratories, West Point, Pennsylvania 19486,4 Infectious Disease/Vaccines, Merck Research Laboratories, Upper Gwynedd, Pennsylvania 194545
Received 18 December 2008/ Returned for modification 8 January 2009/ Accepted 17 March 2009
A direct binding Luminex assay has been developed and validated for the detection of human immunoglobulin G (IgG) antibodies to the Staphylococcus aureus iron surface determinant B protein (IsdB) in serum following natural infection or immunization with investigational Saccharomyces cerevisiae-derived IsdB-based vaccines. To ensure that IsdB-specific IgG antibodies are measured following immunization with S. cerevisiae-derived IsdB, an Escherichia coli-produced IsdB antigen is used in the assay. The IsdB antigen is covalently conjugated to maleimide microspheres via an engineered carboxy-terminal cysteine residue. Antibody titers are determined in a direct binding format, where the phycoerythrin-labeled monoclonal antibody (HP6043) specific for IgG1 to IgG4 binds to human serum IgG antibodies. Fluorescent signal emitted from bound HP6043 is directly proportional to an individual's antibody levels. A pooled human reference serum from vaccinees with high titers to IsdB is used to generate a 12-point standard curve. The correlation of mean fluorescent intensity (MFI) units to µg/ml of IsdB-specific IgG is made by interpolating the MFI data through a four-parameter curve-fitting algorithm. The assay is sensitive to 1.06 µg/ml with a dynamic range of 2.1 to 10,625 µg/ml. The overall specificity of the assay is >96% and the linearity (parallelism) of the assay is –4% per 10-fold dilution. The total precision of the assay was 16.6% relative standard deviation across three different IsdB antigen lots, three different microsphere lots, two secondary antibody lots, and three different operators. The assay has proven useful for evaluating the immune response following the administration of different dosages and formulations of investigational IsdB-based vaccines.
Published ahead of print on 25 March 2009.
Current address: Pharmaceutical Product Development Vaccines and Biologics, Wayne, PA.
Current address: Wyeth Vaccines, Pearl River, NY 10965.
Copyright © 2009 by the American Society for Microbiology. For an alternate route to Journals.ASM.org, visit: http://intl-journals.asm.org | More Info»