Center of Excellence for Flow Cytometry, Office for Research and Development, Faculty of Medicine, Siriraj Hospital, Mahidol University, Bangkok, Thailand,1 Thailand Ministry of Public Health-U.S. CDC Collaboration, Nonthaburi, Thailand,2 Bureau of AIDS, TB and STIs, Department of Diseases Control, Ministry of Public Health, Nonthaburi, Thailand,3 Division of HIV/AIDS Prevention, Centers for Disease Control and Prevention, Atlanta, Georgia,4 Global AIDS Program, Centers for Disease Control and Prevention, Atlanta, Georgia5
Received 14 May 2005/ Returned for modification 29 July 2005/ Accepted 16 September 2005
Use of the standard dual-platform flow cytometric method for determination of CD4+ T-lymphocyte counts, which needs both a flow cytometer (FCM) and hematological analyzer, would inevitably lead to increased variability. The development of new single-platform (SP) FCMs that provide direct CD4+ T-lymphocyte counts for improved assay precision and accuracy have recently attracted attention. This study evaluated one of those systems, CyFlowgreen (Partec), a single-parameter SP volumetric FCM. The performance of CyFlowgreen was compared with those of two reference standard SP microbead-based technologies of the three-color TruCOUNT tube with the FACScan FCM and a two-color FACSCount system (Becton Dickinson Biosciences). Absolute CD4+ and CD8+ T-lymphocyte counts in 200 human immunodeficiency virus type 1-seropositive blood specimens were determined. Statistical analysis for correlation and agreement were performed. A high correlation of absolute CD4 counts was shown when those obtained with CyFlowgreen were compared with those obtained with the bead-based three-color TruCOUNT system (R2 = 0.96; mean bias, 69.1 cells/µl; 95% confidence interval [CI], 225.7 to +87.5 cells/µl) and the FACSCount system (R2 = 0.97; mean bias, 40.0 cells/µl; 95% CI, 165.1 to +85.1 cells/µl). The correlation of the CD4+ T-lymphocyte counts obtained by the two bead-based systems was high (R2 = 0.98). Interestingly, CyFlowgreen yielded CD4+ T-lymphocyte counts that were 21.8 and 7.2 cells/µl lower than those obtained with the TruCOUNT and the FACSCount systems, respectively, when CD4+ T-lymphocyte counts were <250 CD4+ T-lymphocyte counts/µl range or 17.3 and 5.8 cells/µl less, respectively, when CD4+ T-lymphocyte counts were <200 cells/µl. The single-parameter CyFlowgreen volumetric technology performed well in comparison with the performance of the standard SP bead-based FCM system. However, a multicenter comparative study is needed before this FCM machine is implemented in resource-limited settings.
| Antimicrob. Agents Chemother. | Clin. Microbiol. Rev. | Infect. Immun. |
|---|---|---|
| J. Clin. Microbiol. | J. Virol. | ALL ASM JOURNALS |